Technology-dependent children are those who are reliant on a medical device to augment (or completely replace) a vital bodily function to sustain life.
Respiratory support, nutritional support, indwelling venous catheters, cerebrospinal fluid shunts.
Case: You respond to a call at a chronic care facility where a 5-year-old male with a tracheostomy is having difficulty breathing and intermittent oxygen desaturations.
Acquired respiratory dysfunction (e.g., prolonged mechanical ventilation)
Congenital respiratory dysfunction (e.g., bronchopulmonary dysplasia)
Acquired neurological problems (e.g., hypoxic-ischemic encephalopathy)
Chronic neurological problems (e.g., central hypoventilation)
Anatomic airway obstruction (e.g., subglottic stenosis)
Tracheostomy tubes contain several parts ( Fig. 39.1 ). All tracheostomy tubes contain an outer cannula , which serves to hold the tracheostomy open, and a neck plate (flange) that sits on the child’s neck and contains two holes for a tie that wraps around the neck to secure the tracheostomy in place. The outer cannula may or may not have a cuff that can be filled with water or air. There may be an inner cannula that fits snuggly inside the outer cannula and can be removed to facilitate the cleaning of the tracheostomy tube. An obturator is a small rigid stylet that fits inside the tracheostomy tube to help guide the tube into place during insertion. The obturator must be removed after insertion so that the child can breathe through the tracheostomy tube.
There are several variables relating to pediatric tracheostomy tubes, and it is crucial to be specific when requesting a tube. Variables include the A ge range (PEDiatric or NEOnatal), B rand (e.g., Shiley), C uffed vs. uncuffed, and S ize (the diameter of the outer cannula)—otherwise known as the ABCs . This information is typically printed on the neck plate of the tracheostomy tube ( Fig. 39.2 ).
Oxygen and appropriate delivery system (stoma mask and face mask)
Bag-valve mask
Suction
Tracheostomy tubes (anticipated size and one size smaller)
Sterile lubricant
Syringe (for a cuffed tracheostomy tube)
The first step is to attempt to suction the tracheostomy tube. If there is an inner cannula, this can be removed to facilitate suctioning. If symptoms resolve after suctioning of the tube, there is no need for tracheostomy tube replacement.