Electroencephalographic Artifacts


An artifact is a waveform in the EEG that is not of cerebral origin. Those new to the world of EEG interpretation are often surprised to learn that at least half the challenge of EEG reading consists of identifying artifacts correctly so as not to mistake them for true EEG (cerebral) activity. This is quite different from other types of interpretation in clinical electrophysiology such as electrocardiogram (EKG) reading in which the problem of distinguishing electrical artifact from actual EKG waves is only occasionally a problem.

The mistake of interpreting an electrical artifact as a true EEG wave can have important negative consequences. Reporting an innocent “electrode pop” artifact as an epileptiform spike is an error that can have serious clinical repercussions. Unfortunately, mistaking an artifact for an EEG wave is not an uncommon type of error among inexperienced readers—even experienced readers can find the distinction between electrocerebral activity and artifact difficult at times. For these reasons, new readers should devote considerable energy to mastering the thought process used to distinguish artifacts from true EEG activity.

Some of the most common EEG artifacts are so distinctive in appearance that the experienced reader rapidly screens them out without the need for close analysis. A good example of this is muscle artifact. Muscle artifact from the temporal, frontal, and occipital areas is so frequently encountered that, for some portions of the tracing, the challenge of interpretation is to “read through” these artifacts to see the true EEG activity.

Artifacts are not always a hindrance to EEG interpretation. Sometimes they can yield valuable information. The presence of the same muscle artifact that obliterates the EEG from the temporal areas may also serve as a useful indicator that the patient is moving and awake rather than asleep. Likewise, the presence of eyeblink artifact would not be expected in the sleeping patient and therefore helps to exclude the possibility that the patient is asleep. Other types of eye movement artifact can help identify sleep stages. The presence of slow roving lateral eye movement artifact is often a useful sign of drowsiness. The presence of REM (rapid eye movement) sleep is confirmed, as its name suggests, by the presence of REM artifact. Other types of artifact, however, can be a real hindrance to EEG interpretation. A patient who is constantly moving may generate a record so dominated by motion artifact as to render it uninterpretable. In some patients, the motor activity associated with a seizure can generate so much muscle and motion artifact that the underlying EEG seizure discharge cannot be identified.

STRATEGIES OF ARTIFACT RECOGNITION

There are two main principles that are critical to the process of distinguishing what is “real” brain wave activity from artifact in the EEG record. The first is wave morphology, or using the shape of a wave to determine its nature; certain wave shapes and patterns are highly characteristic of certain types of artifacts. The second is the principle of “biologic plausibility”; electrical events of cerebral origin should show a distribution of intensity on the scalp surface that is plausibly consistent with brain wave activity. Artifacts may show a topography of voltages that is bizarre and unpredictable indicating a biologically implausible event. When an event has a biologically implausible topography, the EEG reader is more likely to interpret it as electrical or motion artifact. We expand on these concepts in the examples that follow.

Wave Morphology

Certain artifacts in the EEG have characteristic shapes, such as eyeblink artifact, muscle artifact, and some electrode pops. Some of these artifacts have such a specific appearance that their identification essentially consists of a “sight diagnosis” or pattern recognition. The conclusion that some waves represent artifact may require a combination of both techniques, wave pattern recognition and analysis of wave topography. Examples of various specific types of artifact are shown later in this chapter.

“Biological Plausibility” Versus “Biological Implausibility”

Although some artifacts can be recognized on the basis of the shapes of their waves, the most powerful tool in distinguishing a true brain wave from an artifact is to establish its specific topography. Here, the major operating principle is that biological events recorded on the scalp tend to have a point of maximum voltage with the surrounding measured voltages diminishing with varying steepness from the point of maximum (see Figure 6-1 ). The voltage gradients seen with electrocerebral events are expected to have some degree of “smoothness.” In contrast, the electric fields of artifacts may have a patchy and unpredictable contour (compare to Figure 6-2 ).

Figure 6-1, A schematic depiction of a pure negativity occurring on the scalp, maximum in the left parietal electrode (P3). Note that the intensity of the negative fields, denoted by the number of minus signs, dissipates gradually away from the maximum, but with varying “steepness” in different directions.

Figure 6-2, In contrast to the previous figure, the field of this discharge is scattered and patchy, showing different polarities in different locations. The pattern of this scalp electrical event does not seem “plausible” for electrocerebral activity. Patterns such as these are most likely caused by electrical or motion artifact.

A second principle is that the polarity of most discharges tends to be consistent. Most discharges, if negative at their maximum point, remain negative wherever they are detected on the scalp as shown in Figure 6-1 . In general, negative events tend to be negative everywhere, and positive events tend to be positive everywhere. Exceptions to this rule exist, including the occasional examples of discharges that manifest a so-called horizontal dipole (the example of the “horizontal” or tangential dipole is discussed in detail in Chapter 10 , “The EEG in Epilepsy”). Even in the small minority of epileptiform events that manifest a simultaneous combined positivity and negativity, those areas of opposite charge are usually segregated in a simple and orderly fashion rather than showing a pattern of several separated regions of positivity and negativity (see Figure 6-3 ).

Figure 6-3, A schematic of a “horizontal dipole” is shown, a relatively uncommon finding outside of benign rolandic epilepsy and related syndromes. In contrast to most discharges that show a single polarity on the scalp at any one time (usually negative), in this example, a negative charge and a positive charge are recorded on the scalp simultaneously. Even though both polarities are present, the transition between the two is smooth. The configuration shown here of a negativity in the centrotemporal area and a positivity in the anterior head regions is characteristic of the so-called rolandic spike, discussed in more detail in Chapter 10 , “The EEG in Epilepsy.”

Patterns with significant charge inconsistencies are also not expected from biological systems. The example of an apparent discharge with strong negativities in the left posterior quadrant and the right anterior quadrant but no measured voltage change in the intervening areas as depicted in Figure 6-4 is not likely of cerebral origin. Because this is not a “biological” pattern, there would be a strong suspicion of motion or some other type of artifact having affected two distant electrodes. This pattern and the pattern that was seen in Figure 6-2 may be produced by the haphazard jostling of electrodes during patient movement.

Figure 6-4, A localized negativity is seen in the left posterior temporal area simultaneously with a strong negativity in the right frontopolar area. The intervening areas are electrically neutral. This field does not seem consistent with the biology of the brain. Rather, this pattern, which lacks a gradient and only involves two individual but distant electrodes, is much more suggestive of electrode or motion artifact than a true electrocerebral discharge.

Whenever analyzing any wave on the EEG page, the reader should visualize the voltage topography of the discharge to confirm a distribution of charge that is potentially consistent with cerebral activity. Usually with a bit of practice this can be done quickly. Discharges with bizarre or unpredictable electrical fields likely represent artifact. The importance of localization skills cannot be overemphasized and it is for this reason that the techniques of localization discussed in Chapter 4 , “Electroencephalographic Localization,” should be mastered before moving on.

How do such “biologically implausible” artifacts arise in the first place? Most such artifacts are related to head motion. When the patient’s head moves, some combination of electrode wires is tugged on. The pattern of wires that is pulled with a head movement is, for the most part, unpredictable and may not follow any particular spatial pattern on the scalp. Disparate and distant deflections on the scalp, especially with varying polarities, are much more suggestive of motion artifact than of electrocerebral activity.

A type of motion artifact that might reliably follow a spatial pattern is head rolling or rocking. In such instances, the electrodes lying against the bed are most susceptible to motion artifact. For example, if the occipital portion of the patient’s head is in contact with the bed, head motion artifact will tend to be most dramatic in the occipital electrodes. Likewise, if the patient is lying on the left side of the head, the left temporal electrodes will be most prone to motion artifact. Artifact may appear in these or other electrodes with voluntary head movements, or even with the low-amplitude head movements associated with the patient’s respirations.

Some significant EEG diagnostic challenges occur when patients are referred for the question of whether sudden movements are epileptic. The diagnostic problem is made more difficult in that each movement may generate a motion artifact causing the appearance that each is correlated with an EEG burst. There would be no difficulty if the movement in question were, for instance, a nonepileptic twitching of the hand because a hand movement would not cause motion artifact in distant scalp electrodes. The hand movement would occur during the study, and there would be no EEG change, strongly suggesting that the hand movements were nonepileptic. If the movement involves the head, however, there may be a simultaneous burst in the EEG, creating some confusion as to whether the movement caused the wave (and is an artifact) or the wave caused the movement (and is an epileptiform discharge). The approach to this problem takes into account that when the head moves, is turned on the pillow, or is subject to some other type of external movement, the pattern of electrodes that are disturbed tends to be more random. Artifacts caused by electrode motion or head motion tend to show a nonregular distribution of inconsistent voltages like those shown in Figures 6-2 and 6-4 . In comparison, the patterns associated with electrocerebral activity are expected to show more consistent polarities and a voltage gradient that tapers with distance from the point of maximum.

A second approach to this type of problem is to analyze the way in which the EEG discharge is time-locked to the movement. When a movement is caused by an EEG burst (e.g., epileptic myoclonus), there is always a slight time lag between the EEG burst and the movement because it takes some amount of time for the cortical signal to propagate through the nervous system to the muscles. This latency between the burst and the movement may be confirmed either by a synchronized video recording of the patient or an electrode placed on an involved limb. With use of the latter, the EEG burst appears first, followed by the muscle burst in the limb electrode. If an apparent EEG burst is really an example of motion artifact, the two are generally seen to occur on the video simultaneously, or the body movement may even start before the EEG deflection.

SPECIFIC TYPES OF EEG ARTIFACT

Artifacts Associated With Eye Movements

Eyeblink Artifact

Electroencephalographers know that when individuals close their eyes, the globes of the eyes deviate upward. This comes as a surprise to some because when we watch a person casually blink or close the eyes, this upward movement of the globes is hidden from view by the closed eyelids. It is only in special situations that this reflex upward eye deviation with eye closure, termed Bell’s phenomenon, is readily observable. Bell’s phenomenon becomes strikingly evident in the case of individuals who suffer from Bell’s palsy. In Bell’s palsy, there is a paralysis of the facial nerve (cranial nerve VII), one of whose functions is to close the eyes. The nerves that move the globe of the eye (cranial nerves III, IV, and VI) are unaffected in patients with Bell’s palsy. Therefore, Bell’s palsy patients have normal eye movement but cannot close the affected eyelid. Thus, the facial nerve paralysis caused by Bell’s palsy literally uncovers Bell’s phenomenon—we can see what the globe of the eye is doing during intended eyelid closure. Bell’s palsy patients have normal eye closure on the unaffected side, but when blinking or closing the eye on the paralyzed side, the globe of the eye can be seen to deviate upward, unhidden by the eyelid. Upward deviation of the globes may also be seen when a person’s eyelids are forcibly pried open during attempted voluntary eye closure. Finally, in some individuals who are in the process of falling asleep, especially babies, the eyelids may lower to a “half-mast” position but do not completely close. Because of a partial Bell’s phenomenon associated with the partial eye closure, only the whites of the eyes can be seen in the half-open palpebral fissures.

The type of artifact that an upward movement of the globes might cause during eye blinking or eye closure is not intuitively obvious without knowing that the globe of the eye has a particular distribution of charge. As it happens, the cornea (the front of the globe of the eye) carries a net positive charge and the posterior pole of the globe carries a net negative charge, forming a dipole. Because of the presence of this positive charge on the cornea, the bobbing upward of the eye with eye closure is easily detected by EEG electrodes. Figure 6-5 illustrates how the EEG electrodes closest to the eye “perceive” an eyeblink. With upward eye deviation, the electrodes closest to the globes, Fp1 and Fp2, perceive the strong positivity of the corneal surfaces. The F3 and F4 electrodes, which are immediately posterior to the Fp1 and Fp2 electrodes, also pick up some of this positivity, but to a much lesser degree than the Fp1 and Fp2 electrodes. With Fp1 being more positive than F3 and Fp2 being more positive than F4, the Fp1-F3 and Fp2-F4 channels show the characteristic sharp, downward-sweeping waveforms of eyeblink artifact (see Figure 6-6 ). A similar type of artifact is seen with eye fluttering (see Figure 6-7 ).

Figure 6-5, This figure shows how the dipole across the globe of the eye leads to the appearance of eyeblink artifact on the EEG. The cornea of the eye carries a net positive charge relative to the posterior pole of the eye, which carries a net negative charge. When the eyes are blinked or closed, the globes of the eye deviate upward under the closed eyelids (Bell’s phenomenon). This results in the exposure of the Fp1 electrode in the diagram to the net positivity of the cornea. The F3 electrode, which is more distant from the cornea, also picks up some of the positivity, but to a lesser extent. Thus, when the eyes bob upward as shown in the right panel, the Fp1-F3 channel deviates downward (Fp1 is more positive than F3). When the F3 electrode is compared with the C3 electrode (not shown), the smaller amount of positivity picked up by the F3 electrode is compared to the neutral C3 electrode (C3 is too distant from the cornea to detect this event), and the F3-C3 channel shows another, smaller downgoing wave. More posterior channels in AP bipolar chains would not be expected to show deflections from eyeblink artifact.

Figure 6-6, The typical appearance of eyeblink artifact showing high voltage downward deflections in the top two channels of each four-channel chain of the standard anteroposterior bipolar montage. Asterisks at the top of the page denote the timing of each eyeblink artifact. Note that, in each set of four channels, the deepest deflection is seen in the top channel. A less intense deflection is seen in the channel just below the top channel in each channel. Eyeblink deflections are not seen in the more posterior channels. The presence of repetitive eyeblink artifact usually indicates that the eyes are open. This is consistent with the observation in this figure that the posterior rhythm disappears at the time of the eyeblink artifact. The technologist has made a notation confirming this.

Figure 6-7, An artifact similar to eyeblink artifact is seen during eye fluttering. In this example, the eye fluttering is caused by the repetitive flashes of the strobe light during photic stimulation (note strobe flashes in the bottom channel). Occasionally, eye fluttering or eye bobbing artifact can be difficult to distinguish from frontal slow-wave activity. In such cases, special electrodes placed below the eyes can help distinguish between the two possibilities. Muscle artifact is seen in each temporal area.

A useful general rule regarding eyeblink artifact is that it should not be detectable in the electrodes of the posterior half of the head; movements of the globes of the eye should not be perceived by the parietal or occipital electrodes because they are too distant. Eyeblink artifact is only occasionally picked up by the central electrodes, C3 and C4, and when it is it should be of low voltage (see Figure 6-8 ).

Figure 6-8, Three eyeblink artifacts are shown in a referential montage, with each active electrode compared to a CS2 reference, a location on the back of the neck distant from the eyes. The artifact is of high voltage in the Fp1 and Fp2 channels and is picked up to a lesser extent in F7 and F8. More posterior channels are neutral. Low-voltage EKG artifact can be seen in all channels indicating that it is being picked up by the reference electrode.

Lateral Eye Movement Artifact

An extension of this same phenomenon involving the motion of the positive charge on the anterior aspect of the globe is used to understand the appearance of lateral eye movement artifact. In the case of lateral eye movements, the anterior temporal electrodes, F7 and F8, are the electrode contacts best placed to perceive the positivity of the cornea as the eyes move from side to side in the horizontal plane. For example, when a patient gazes to the left, the F7 electrode picks up a net positivity. Simultaneously, as the eyes gaze to the left, the F8 electrode picks up a net negativity from the posterior pole of the globe (see Figure 6-9 ). This results in a characteristic pattern seen with a simultaneous “positive phase reversal” in the anterior temporal electrode on the side to which the eyes have turned and a “negative phase reversal” in the anterior temporal electrode on the side away from which the eyes have turned. In the case of more rapid voluntary saccades or REM sleep, these lateral eye movement artifacts can have a squared-off appearance at wave onset. During drowsiness, slow roving lateral eye movements may be seen in which the artifact shows a more rounded appearance (see Figure 6-10 ). Therefore, identification of both eyeblink and lateral eye movement artifact requires a combination of wave pattern recognition and localization of the electrical events to their characteristic locations.

Figure 6-9, Lateral eye movements create a specific type of artifact in the EEG. The diagram here shows the example of both eyes gazing to the right, as seen from above. Because the cornea holds a net positive charge and the posterior pole of the eye a net negative charge, a lateral eye movement creates opposing situations for each pair of frontopolar and anterior temporal electrodes (Fp1 and F7, Fp2 and F8). When the eyes move to the right, the right anterior temporal electrode (F8) is exposed to the positive charge of the cornea of the right eye. With F8 being more positive than Fp2, the “positive phase reversal” depicted above the right eye results. At the same time, the left anterior temporal electrode is exposed to a net negative charge by the medial movement of the left eye, as shown in the figure. This results in a simultaneous “negative phase reversal” appearing at the left anterior temporal electrode (F7). Lateral eye movements are therefore identifiable by the very characteristic simultaneous appearance of a “negative phase reversal” in one anterior temporal electrode and a “positive phase reversal” in the opposite anterior temporal electrode.

Figure 6-10, Slow roving lateral eye movements of drowsiness have a characteristic appearance based on the polarities seen with lateral eye movement artifact, as described in the previous figure. In this example, “negative phase reversals” are seen in the F7 electrode at the same time as “positive phase reversals” are seen in the F8 electrode (arrows). Each electrode experiences positivities and negativities of more or less equal duration, reflecting sequential slow shifting of the eyes to the left and then to the right under closed eyelids. This differs from voluntary saccadic movements, which manifest sharper waveforms and also do not typically give equal time to the leftward and rightward phases of the movements.

Slow Roving Eye Movements of Drowsiness and Sleep

Slow roving eye movements of drowsiness mentioned earlier represent an important example of lateral eye movement artifact. This type of eye movement shows an electrical pattern that is similar to other lateral eye movements, with a “positive phase reversal” at the anterior temporal electrode on the side to which the eyes are moving and a “negative phase reversal” at the opposite anterior temporal electrode. The slow roving version of lateral eye movements has a distinctively rounded, more prolonged shape (see Figure 6-10 ). In contrast, lateral eye movements occurring during wakefulness or during REM sleep tend to be quicker and have a more squared-off onset. Correct identification of eyeblink artifact and the various lateral eye movement artifacts can be helpful in determining sleep stage.

You're Reading a Preview

Become a Clinical Tree membership for Full access and enjoy Unlimited articles

Become membership

If you are a member. Log in here